Sealed swing doors.

Designed for areas where air, dust and contaminants must be controlled: operating theatres, intensive care units, isolation rooms, infectious disease wards and cleanrooms. On closing, the leaf moves against the wall and lowers onto the floor, compressing the seals on all four sides.

img_0706.jpeg

Sealed doors, certified performance.

Used where air, dust and contaminants must be controlled: operating rooms, intensive care, isolation rooms, infectious diseases and clean rooms. When closing, the door leaf moves up to the wall and drops to the floor, pressing the seals on all four sides.

eyJpdCI6Ikhvc3BpdGFsIERpdmlzaW9uIn0=

Certified

HD60 Profile

Coplanar

We design and build hinged and sliding doors for hospital settings where control of air, noise and contamination is non-negotiable.

Doors certified to UNI EN 14351-1:2016 (CE marking) and classified for air permeability according to EN 12207; automated versions also meet the safety and performance requirements of UNI EN 16361:2016, ensuring sealing and compliance for hospital environments.

A dedicated profile, designed to ensure maximum airtightness and protection from contamination, while maintaining structural strength and ease of cleaning and sanitizing.

ABET laminate panel flush with the aluminum profile: seamless surface, with no visible joints, easy to clean and sanitize.

Automatic 

or manual

With interlock system

Various finishes

Available both in a manual version, with handle and lock, and in an automated version, to suit the different operational needs of departments and traffic flows.

Interlock system that prevents the simultaneous opening of multiple doors, ensuring differential pressure control and the safety of areas at risk of contamination.

Wide range of finishes and colors to match the aesthetic and functional standards of every department, without compromising the sealing performance and hygiene required.

 

Hermetic doors

38caee8d-c030-412d-800c-dd236a1504a7battente%20automatica%20a%20tenuta%20img_1863.jpegporta%20battente%20manuale%20tenuta%20ermetica%20(caserta)%20copia.jpegimg_0679.jpegff41bf9e-4e6a-4617-8af2-e85fd6880d82.jpegimg_1243.jpeg

Maximum sealing, maximum safety for healthcare settings

Our sealed swing doors are designed to meet the strictest needs of hospital and healthcare environments, where controlling air, dust and contaminants is an essential requirement.

 

Main features

  • Door leaf with perfect contact on the perimeter gaskets, for optimal sealing in the closed position
  • Sturdy structure with antibacterial handle and lock, designed for intensive use typical of healthcare facilities
  • Available in manual version or pre-set for automation, to suit high-traffic routes or controlled-access areas
  • Materials and finishes compliant with the hygiene-health standards required in hospital settings

Explore the door in 3D

 

Rotate the model, move components apart with the slider and tap the numbers to take a closer look at each part.

Technical documentation and certifications. 

Specification items  

Product sheet

 

In this area you can view and download all the documentation related to our products: technical drawings, certifications, data sheets and manuals, to support you during the design, specification and installation phases..

Leak-tightness certification

Technical drawing

96ff693b-e377-4e3a-9569-1e8555d434d5

Choose the color you like most.

 

Complete the door with the color of the HPL panel and the perimeter aluminum profile.

eyJpdCI6IiJ9
eyJpdCI6InBvcnRhIGEgdGVudXRhIGVybWV0aWNhICJ9eyJpdCI6InBvcnRhIGEgdGVudXRhIGVybWV0aWNhICJ9eyJpdCI6InBvcnRhIGEgdGVudXRhIGVybWV0aWNhICJ9eyJpdCI6InBvcnRhIGEgdGVudXRhIGVybWV0aWNhICJ9eyJpdCI6InBvcnRhIGEgdGVudXRhIGVybWV0aWNhICJ9eyJpdCI6InBvcnRhIGEgdGVudXRhIGVybWV0aWNhICJ9

Latest 

supplies.

Catalog 2026.

eyJpdCI6IiJ9

Request a consultation


Contact us for a free technical assessment and discover the solution best suited to your facility.

whatsapp image 2026-09-21 at 15.04.07.jpeg

Blog

Technical guides

blog-detail

Porte a tenuta semplice vs porte a tenuta: differenze
Porte a tenuta, porte-scorrevoli-a-tenuta, stanze-di-isolamento, porte-a-tenuta, porta-a-tenuta-semplice, porte-battenti-a-tenuta, sala-operatoria, capitolato-porte, uni-en-12207,

Porte a tenuta semplice vs porte a tenuta: differenze

Massimiliano Fricano

05-10-2026 09:16

Guarnizioni o sistema a pressione? Cosa distingue una porta a tenuta semplice da una porta a tenuta, dove serve ciascuna e quali errori evitare in capitolato.

Porta scorrevole a tenuta per sala operatoria: guida tecnica alla scelta
Porte a tenuta, porte-sala-operatoria, porte-ospedaliere, porta-scorrevole-a-tenuta, blocco-operatorio, uni-en-16005,

Porta scorrevole a tenuta per sala operatoria: guida tecnica alla scelta

Massimiliano Fricano

05-10-2026 07:40

Come scegliere una porta scorrevole a tenuta per sala operatoria: tenuta, igiene, automazione UNI EN 16005 e opzioni da prevedere in progetto.
whatsapp image 2026-09-21 at 15.04.07.jpegb19154c0-d3af-4e4b-8330-245feb74625e7233c6ab-ecef-4cf9-ab62-26e842944b5c81e6b375-ff6c-4626-b08a-0be7f21b78417535ecdd-0520-44e3-b2e3-675d2f484c89e6f64549-1dfb-4a40-9b76-86a1644c339ea6ffc05a-1a4b-4841-b108-21786ad8fae204f398a4-aa14-430b-b99a-d8d674de4bf7c3407d90-0e3c-4818-b265-d9a09686a67818e90da1-ab05-4625-8dbf-29021a46846a9341b89e-41f4-443e-a57e-42d4cf1f535a5f584559-440f-4cac-a5db-2d7f2ed89a43
G-FJP0PHKX9NG-FJP0PHKX9N